Product

Ingersoll Rand 49164395 Air Filter Element | Donaldson FPG10 RadialSeal

Ingersoll Rand 49164395 air filter element built to Donaldson FPG10 two-stage RadialSeal specifications. 99.9% filtration efficiency (ISO 5011), 208 mm OD x 106 mm ID x 409 mm length, 2000-hour service interval. Export-ready for compressor distributors and OEM procurement.

Contact Sales WhatsApp
  • Export packaging & documentation support
  • OEM / ODM customization available
  • Sample and bulk order workflow

Product Overview

49164395 is the intake air filter element used on Ingersoll Rand rotary screw air compressors, manufactured to Donaldson FPG10 specifications.

Unlike a conventional single-stage air filter, FPG10 is a two-stage intake filtration system. Air first passes through an integrated tangential pre-cleaner, where the tangential airflow spins at high speed and centrifugal force drives coarse particles to the housing wall. Approximately 85% of coarse dust is separated before reaching the primary element and is automatically discharged through the Vacuator dust valve at the base of the housing. Pre-cleaned air then enters the primary element, where cellulose filter media performs fine filtration. This architecture matters most in dusty environments: the primary element carries only fine-particle load, maintaining longer service life under high-dust conditions.

The sealing method also differs from traditional air filters. FPG uses Donaldson's RadialSeal technology: a one-piece molded polyurethane end cap forms a radial seal directly against the housing outlet tube, eliminating the glued gasket of older axial elements. Fewer parts means fewer failure points — gasket aging, detachment, and installation misalignment are eliminated in the FPG design, and no tools are required for removal or installation.

Core Specifications

ItemValue
Part Number49164395
Product NameAir Filter Element
BrandIngersoll Rand
Specification SourceDonaldson FPG10 (two-stage RadialSeal)
Role in AssemblyPrimary Element
Dimensions208 mm OD x 106 mm ID x 409 mm length
Sealing TypeRadialSeal (polyurethane end cap, no gasket)
Net WeightApprox. 1.88 kg
Filtration Efficiency99.9% (ISO 5011)
Pre-Cleaner EfficiencyUp to 85% coarse dust removal
Rated AirflowUp to 346 cfm / 9.8 m3/min
Recommended Service Interval2000 hours or 3 months

Technical Specifications

Filtration Performance

ParameterValue / Notes
Filtration Rating5 micron class (primary element)
Filtration Efficiency99.9% (tested per ISO 5011)
Pre-Cleaner EfficiencyUp to 85% coarse dust removal (tangential pre-cleaner stage)
Filter ClassTwo-stage: centrifugal pre-cleaner + cellulose primary element; HVAC filter classification (EN 779) does not apply
Dust Holding CapacityApprox. 1200 g

Practical difference of the two-stage design: in a single-stage filter, the media must handle both coarse and fine particles; coarse dust accumulates rapidly on the surface, resistance rises quickly, and service life is short. FPG10 transfers the coarse-dust burden to the centrifugal pre-cleaner stage, significantly improving the load profile of the primary element — a key reason it is widely adopted on construction machinery and generator sets operating in dusty conditions.

Flow and Resistance

ParameterValue / Notes
Rated AirflowUp to 346 cfm / 9.8 m3/min (filter assembly rated intake)
Filtration Face VelocityApprox. 0.038 m/s
Initial Pressure DropApprox. 0.5-1.0 kPa (approx. 50-100 mmH2O)
Operating Differential RangeFrom new-element initial resistance to clogging alarm threshold
Alarm / Final ResistancePer the machine's restriction indicator yellow/red zone
Pressure Drop vs. EnergyEach 1 kPa increase in intake resistance adds roughly 1% to machine energy consumption

Pressure drop and energy consumption

Rising intake resistance lowers intake pressure and density; the machine must do more work to maintain set discharge pressure and flow, and specific power rises. Calculated at 0.7 MPa discharge pressure and 101.3 kPa atmospheric pressure:

Intake ResistanceCompression RatioRelative Energy Increase
0 kPa (new element)7.91Baseline
2 kPa8.07+2.0%
4 kPa8.24+4.1%
6 kPa8.41+6.3%

Engineering implication: as an element progresses from new to heavily clogged (0 to 6 kPa), machine energy consumption rises by roughly 6%. The cumulative electricity cost typically far exceeds the price of an element — which is why the FPG10 housing provides a restriction indicator port: replacement timing is driven by actual resistance, not calendar estimates.

Dimensions and Installation

ParameterValue / Notes
Dimensions208 mm OD x 106 mm ID x 409 mm length
ConfigurationPleated cylindrical element, two-stage RadialSeal primary element
Effective Filtration AreaApprox. 4.3 m2
Pleat CountApprox. 103 pleats
Pleat SpacingApprox. 4.8 mm
Mounting InterfaceRadial push-in; end cap seals against housing outlet tube
SealingRadialSeal — one-piece molded polyurethane end cap forms radial seal, no separate gasket
Companion ElementSafety element, mounted inside the primary element as backup protection

Procurement note: when cross-checking replacements, verify all three dimensions — 208 mm OD, 106 mm ID, 409 mm length. The FPG design uses radial sealing; push in until the end cap contacts the outlet tube, with no additional gasket. Do not attempt to add a gasket, as it will break the radial seal fit.

Material Construction

ParameterValue / Notes
Filter MediaCellulose filter paper, per FPG10 specification
Media WeightApprox. 130 g/m2
Inner/Outer SupportGalvanized steel perforated support (inner core + outer screen)
End CapOne-piece molded polyurethane (PU) end cap, encapsulating both media ends and sealing surface
Sealing ElementRadialSeal formed by the polyurethane end cap itself; no separate O-ring or gasket
BondingMolded integrally with end cap; no additional adhesive layer

Construction note: a traditional axial element comprises three parts — metal end cap, glued gasket, and separate seal ring — any of which can age and cause bypass. FPG encapsulates the end cap, sealing surface, and media ends in a single polyurethane body, reducing part count and improving seal reliability, which is also the basis for tool-free installation.

Operating Tolerance

ParameterValue / Notes
Operating TemperatureContinuous 83 C
Relative HumidityUp to 80% RH, no condensation
Burst StrengthMedia burst strength approx. 200-400 kPa (per ISO 2758 paper burst test)
Collapse ResistanceElement withstands intake alarm differential without collapse (RadialSeal layered support)
Special FeaturesTwo-stage filtration (integrated tangential pre-cleaner) + Vacuator automatic dust valve
Housing CharacteristicsFPG housing is injection-molded plastic; corrosion-resistant and vibration-resistant

Service Life and Maintenance

ParameterValue / Notes
Service Life2000 hours or 3 months, whichever comes first
High-Dust EnvironmentsFollow the restriction indicator reading; schedule replacement when resistance enters the yellow zone
Shelf LifeApprox. 2-3 years (unopened, dry, ventilated storage)

Applicable Standards

ItemContent
Product StandardISO 5011 (intake air filters for internal combustion engines and compressors — performance testing); efficiency figures are tested to this standard
Design StandardDonaldson FPG / FRG series filter specification (RadialSeal sealing system)
Commonly Cited Test StandardsISO 2941 / 2942 / 2943 / 3723 / 3724 / 3968
Standard Applicability NoteThe ISO 29xx / 37xx series are hydraulic filter test methods. If a supplier can only provide hydraulic filter standards, request ISO 5011 or the OEM specification sheet.

Installation and Maintenance Steps

A key feature of the FPG design is tool-free maintenance; a single service takes about 15 minutes.

  1. Shut down, confirm zero pressure, lock out/tag out
    Stop the machine, disconnect main power, and apply lockout/tagout. Criterion: controller shows system pressure at 0.

  2. Open the FPG filter service cover
    Release the cover latches — FPG uses two spring latches or a twist-off cover, no tools required. Criterion: latches intact, cover not deformed.

  3. Remove the old element
    Grip the polyurethane end cap and pull straight out. Criterion: note that the RadialSeal design has no gasket to peel off — if a residual gasket is found on the housing outlet tube, a non-genuine part was previously installed and must be cleaned off.

  4. Inspect the Vacuator dust valve
    Check the Vacuator valve (rubber duckbill) at the base of the housing. Criterion: valve opens and closes freely, no compacted dust, no obstruction. This is the most commonly skipped step in FPG maintenance and the most consequential — a clogged dust valve disables the pre-cleaner stage, shifting the full dust load to the primary element and sharply reducing service life.

  5. Check the pre-cleaner stage and interior dust traces
    Look for dust bypass tracks inside the housing and abnormal accumulation in the pre-cleaner swirl zone. Criterion: no dust tracks on the inner wall; if tracks are present, inspect the sealing surfaces.

  6. Install the new element
    Push 49164395 into the housing until the polyurethane end cap contacts the outlet tube. Criterion: end cap seated against the outlet tube; no gasket is needed or permitted.

  7. Reinstall the service cover and check the restriction indicator
    Refit the cover and secure the latches. Confirm the restriction indicator is in the green zone; if resettable, press to reset and verify it returns properly. Criterion: green-zone reading, indicator functioning.

  8. Start up and record
    Start the machine, run to operating temperature, and read intake resistance. Criterion: resistance within the new-element baseline range; record date, running hours, and resistance reading.

Installation rule: do not start the machine before the element is seated. If the RadialSeal is not pushed fully into place, air bypasses directly through the gap between end cap and outlet tube, disabling both the pre-cleaner stage and the primary element — equivalent to running with no filter at all.

Frequently Asked Questions

What specification is 49164395?
A two-stage RadialSeal primary element manufactured to Donaldson FPG10 specifications. The integrated tangential pre-cleaner removes approximately 85% of coarse dust first, with the primary element handling fine filtration.

Is it interchangeable with 49101637?
No. 49101637 is FPG09, with different dimensions and rated airflow. Confirmation is simple: read the specification marking on the installed element's end cap — FPG10 means order this part; FPG09 means order 49101637.

Why does this element have no gasket?
Because it uses RadialSeal radial sealing. The polyurethane end cap itself forms the seal against the housing outlet tube, with no glued gasket or separate seal ring. Fewer parts, fewer failure points, and less chance of misinstallation.

What does the Vacuator dust valve do?
It is the discharge port for the pre-cleaner stage. Coarse dust separated by the swirling airflow falls by gravity to the base of the housing and discharges automatically through the Vacuator valve. Once the valve clogs, the pre-cleaner stage fails completely, and all dust is forced onto the primary element. Check it at every element change — this is the critical maintenance action for the FPG design.

How often should it be replaced?
The recommended interval is 2000 hours or 3 months, whichever comes first. More accurately, follow the restriction indicator: schedule replacement when resistance enters the yellow zone. In high-dust locations, replace earlier based on indicator readings.

Can the element be blown clean and reused?
No. This is a dry, disposable element — it cannot be washed or reverse-blown with compressed air. Reverse blowing damages the media fiber structure and creates invisible channels that let unfiltered air pass through, which is more dangerous than not replacing it.

Can a gasket be added to improve sealing?
No, and it is unnecessary. RadialSeal forms its seal through radial compression of the end cap body; adding a gasket pushes the element away from the outlet tube and breaks the seal fit, causing bypass.

The restriction indicator never moves — is that normal?
No. A stuck indicator is a common failure point that can show a "clean" reading when the element is actually clogged. Check at every service that it returns properly when pressed; if it has failed, replace the element on a conservative time-based interval until it is repaired.

How does the FPG plastic housing compare with metal housings?
The FPG injection-molded housing is corrosion-resistant, lightweight, and vibration-resistant, and will not rust in coastal salt-spray or humid environments. The tool-free design also speeds up on-site maintenance. This is why the FPG series is widely used on construction machinery and mobile equipment.

How can I be 100% sure this is the right part?
Three steps: (1) read the specification marking on the installed element's end cap to confirm FPG10; (2) measure the old element's outer diameter and length to verify 208 mm and 409 mm; (3) if the old element has been discarded, provide the model marking on the filter housing and we will cross-reference against FPG specifications.

Compatible Equipment

This part is supplied to Donaldson FPG10 specifications and fits Ingersoll Rand rotary screw air compressors equipped with the FPG10 filter housing.

FPG10 is a Donaldson finished filter assembly specification, adopted by OEMs as a standard intake filtration unit. Key identification points:

ItemSpecification
Filter Housing SpecificationDonaldson FPG10 (element interchangeable with FRG10 series)
Rated Intake AirflowUp to 346 cfm / 9.8 m3/min
Role in AssemblyPrimary Element
Other Specification in SeriesFPG09 — part number 49101637, different dimensions and airflow, not interchangeable
Sealing SystemRadialSeal (polyurethane end cap radial seal)

How to confirm fitment

  1. Preferred: read the specification marking on the installed element's end cap. FPG10 means this part applies; FPG09 means order 49101637.
  2. Alternative: measure the old element's outer diameter and length to verify 208 mm x 409 mm.
  3. Fallback: provide the model marking on the filter housing or a photo of the machine nameplate, and we will cross-reference against FPG specifications.

Note on model coverage

Donaldson FPG10 is a universal filter adopted by multiple OEMs, so the fitment range of this part is not limited to a specific machine model list. The determining factor is whether the filter housing is FPG10, not the machine model itself. If the machine nameplate does not state the filter specification, confirm using any of the three methods above.

Related Components

The FPG10 filter is a complete system; besides the primary element, 7 components are maintained together with this part. Listed by component — function — inspection point:

ComponentFunctionInspection Point
Safety ElementBackup element inside the primary element, protecting downstream if the primary is damaged or during change intervalsTypically replaced on the same interval or every other interval; check media for damage
Vacuator Dust ValveAutomatic discharge port for the pre-cleaner stage, expelling centrifugally separated coarse dustCheck at every element change: valve must open and close freely, no compacted dust, no obstruction
Restriction IndicatorIndicates element clogging level; the authoritative basis for replacement timingCheck that the needle returns properly; connection line must be clear
Service Cover and LatchesTool-free opening structure of the FPG housingCheck latches for cracks and cover for deformation; no air leaks when secured
FPG Housing AssemblyInjection-molded plastic housing with tangential inlet and pre-cleaner swirl zoneCheck inner wall for dust bypass tracks; check plastic for cracks
Intake Hose and ClampsConnect the filter to the machine intake ductCheck for cracks, aging, looseness — bypass leakage is as harmful as no filter
Other Primary Elements in SeriesFPG09 — part number 49101637Different dimensions and airflow, not interchangeable; keep separate in stock

Companion replacement advice: the maintenance value of the FPG10 system centers on whether the pre-cleaner stage is working properly. When changing the primary element, inspect the Vacuator valve and restriction indicator at the same time. Failure of either small part will noticeably shorten primary element life — their cost is far lower than the primary element, yet they determine how long it lasts.